Steam Generator COMMERCIAL SERIES
The Whirl® Steam Generator utilizes the latest advances in technology to ensure precision equipment.

Installation, Operation & Maintenace Manual
| Item # |
Model |
Maximun Cubic Feet Capacity |
KW |
Volts |
Phase |
Amps |
Breaker Size |
Wire Size |
| 94-92010 |
SW-10 |
400 |
10 |
240 |
1 |
42 |
60A |
6AWG |
| 94-92010-3 |
SW-10-3 |
400 |
10 |
240 |
3 |
24 | 30A |
10AWG |
| 94-92012 |
SW-12 |
500 |
11.5 | 240 |
1 |
50 |
70A |
6AWG |
| 94-92012-3 |
SW-12-3 |
500 |
11.5 | 240 |
3 |
29 |
40A |
10AWG |
| 94-92018 |
SW-18 |
800 |
18 |
240 |
1 |
75 |
100A |
3AWG |
| 94-92018-3 |
SW-18-3 |
800 |
18 |
240 |
3 |
43 | 60A |
6AWG |
- The generator's revolutionary LED lighting system simplifies installation and there are monitors to ensure proper electrical and water feed at all times.
- Made of stainless steel tank and components, as well as extensive factory testing under all conditions.
- Commercial and Residential Models available.
COMMERCIAL MODELS COME COMPLETE WITH
- 1 polished chrome steamhead & escutcheon 3/4"
- 1 60 minute ON/OFF mechanical timer in white
- 1 pressure gauge
- 1 site glass
6 Year Limited Warranty. **208 AVAILABLE
Certain wall materials, excessive glass, windows, skylights, ceilings over 7 feet, inadequate insulation, adjoining outside walls may require that a model larger than the cubic feet to be used.
All commercial installations should be 3 phase, must have a blowdown #90-4410, strongly suggested the use of a 24 HR 7 DAY timer #4320 and by CODE must have atemperature control TC-2 #90-4225. The 24 HR 7 DAY timer #4320 is wired in series with the TC-2 #90-4225.
All models are USA and Canadian UL Approved.
ALL MODELS
6 YEAR LIMITED WARRANTY